Search results for "ventral hernia"
showing 10 items of 12 documents
New mesh shape and improved implantation procedure to simplify and standardize open ventral hernia repair: a preliminary report.
2010
Introduction Issues in ventral hernia repair are represented by the need for mesh fixation and how to assure a sufficient mesh overlap of the defect. Aiming to resolve these problems, this study describes a modified technique for ventral and incisional hernia repair based upon a newly developed mesh with a special design. This new type of implant allows broader coverage of the abdominal wall and results in tension- and fixation-free repair. Materials and methods A unique geometrically shaped mesh consisting of a large central body and radiating arms was used to repair ventral or incisional hernia. The mesh was intended not to be point-fixated. The friction of the straps passing through the …
Fixation-free incisional hernia repair in the elderly: our experience with a tentacle-shaped implant.
2016
Background: Incisional hernia in aged patients represents a challenge even for experienced surgeons. Besides increased risk of complications due to comorbidities, mesh fixation and assuring a sufficient mesh overlap of the defect are the main issues in carrying out the repair. Aims: In order to assure broader coverage of the abdominal wall and a tension- and fixation-free repair, a specifically designed prosthesis was developed for the surgical treatment of incisional hernias. The results of a fixation-free incisional hernia repair carried out in elderly patients using a tentacle-shaped implant are reported herewith. Methods: A tentacle-shaped flat mesh with a large central body and integra…
The Synthetic Scaffolds for Ventral Hernia Repair: Perspectives for Regenerative Surgery—Systematic Review
2022
AbstractVentral hernia (VH) frequently affects patients after abdominal surgery. The use of a mesh is often recommended. Different materials are described, from synthetic non-resorbable meshes to biological meshes. New generation meshes, also named scaffolds, aim to combine the advantages of both materials. The aim of this review is to provide an overview of the cytological, histological, biomechanical, and clinical outcomes of the use of the newest resorbable synthetic scaffolds in VH repair, based on experimental studies in a pre-clinical setting. A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and t…
The use of a tailored mesh with special design for ventral hernia repair. Preliminary report
2009
Introduction: The study describes a modified technique for ventral hernia repair based upon a tension free, fixation free, and dynamic compliant implant. Material and methods: A unique geometrical shaped light weighted, large porous polypropylene mesh was created consisting of a large central body and six radial arms, designed to pass through the tissues and hold the mesh in place without tension. We used the mesh in a small exploratory cohort of patients with ventral hernia. The mesh was placed sublay by taking each of the six straps and passing from below the muscle, through the muscle allowing the fixation free strap to sit with friction within the tissues. This was designed to give a te…
Closed Incision Negative Pressure Therapy Achieves Better Outcome Than Standard Wound Care: Clinical Outcome and Cost-Effectiveness Analysis in Open …
2020
BackgroundSurgical site infections (SSIs) and surgical site occurrences (SSOs) are frequent post-operative complications that are dependent on the presence of different risk factors. The use of closed incision negative pressure therapy (ciNPT) is considered a measure by the WHO guidelines for prevention of SSIs. The prevention of SSOs is an extremely important issue in the ventral hernia repair (VHR) surgical field. SSO onset not only affects the patient's quality of life, but can also cause the onset of life-threatening conditions that may require re-hospitalization, re-intervention and often mesh removal. Such outcome can become extremely costly, contributing to increased health care cost…
Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.
2010
Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…
Eight-point compass rose underlay technique in 72 consecutive elderly patients with large incisional hernia
2011
Summary Background Repair of incisional hernia (IH) in the elderly is a challenge for the surgeon. Primary closure is preferable but is not always possible because of high recurrence rates of IH repaired without a prosthesis and/or possible respiratory and cardiovascular complications due to extreme tension of the margins. We report our experience with underlay mesh placement in elderly patients with large IH. Methods A total of 72 patients from January 2003 to December 2009 underwent IH repair involving placement of an intraperitoneal Gore® DualMesh® prosthesis. The prosthesis was first anchored at eight points in a compass rose pattern using a Gore® suture passer and then firmly secured t…
Surgical disaster following hernia mesh infection and erroneous treatment strategy: A case report
2020
Highlights • Hernia mesh infection is easier to prevent than to cure. • A late infected hernia mesh explantation is more challenging than an early one. • Hernia mesh fragmentation following partial explantation burdens its complete removal. • An incorrect surgical strategy could catalyze a chain reaction of complications.
Abdominal wall incisional hernia repair improves respiratory function: results after 3 years of follow-up
2020
Abstract Purpose Hernias severely impact patient quality of life (QoL), and 80% of patients require a surgical operation. Moreover, hernias are responsible for respiratory function alterations. This study aims to investigate the postoperative alterations in respiratory function after open ventral hernia repair in patients with incisional hernia. Methods Patients operated on at the Policlinico “Paolo Giaccone” at Palermo University Hospital between January 2015 and December 2016 were identified in a prospective database. Fifty-one patients were enrolled in the study. The respiratory outcome measures used were forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC ratio…
Preoperative Botulinum Toxin and Progressive Pneumoperitoneum in Loss of Domain Hernias-Our First 100 Cases
2020
Objectives: Preoperative botulinum toxin type A (BT) and progressive pneumoperitoneum (PPP) are useful tools in the preparation of patients with loss of domain hernias (LODH). The purpose of our retrospective study is to report our experience in the treatment of 100 consecutive patients with LODH, with the combined use of these techniques. Methods: Of the 753 patients operated on for ventral incisional hernia between June 2010 and December 2018 in our hospital, 100 patients with LODH were analyzed retrospectively. Diameters of abdominal cavity and hernia sac, and volumes of incisional hernia (VIH) and abdominal cavity (VAC) were calculated from CT scan, based on the index of Tanaka. Results…